Number of Bacteria in the Air of Waiting Room in the Public Health Center

Authors

  • fahrul islam politeknik kesehatan kementerian kesehatan mamuju
  • haeranah ahmad poltekkes kemenkes mamuju
  • askur poltekkes kemenkes mamuju

DOI:

https://doi.org/10.25311/keskom.Vol8.Iss2.1109

Abstract

Air quality in the public health center waiting room as one of the facilities of public places is influenced by several factors including; room condition, humidity, temperature, lighting, and microbiological content. Nosocomial infectious diseases are often sourced from health facilities where healthy people can become sick and sick people can gain additional burden from the spread of pathogenic microbes in the air. The purpose of this study is to find out the amount of airborne bacteria in the waiting room of puskesmas in Mamuju subdistrict. This study is an observational study with a descriptive approach through measurement and laboratory examination. The air bacteriological sampling method uses the volumetric air sampling method. The tool used in the capture of airborne bacteria in this study was Microbio MB2. The tool used to measure temperature and humidity is Humidity Alert II Extech 445815 and the tool for measuring lighting is Digital Light Meter TASI-8720 Sampling is done in the morning for 3 (three) days in a row. The results of the study: The average temperature in the waiting room of the public health center of Binanga is 29.80C, while the public health center of Bambu is 28.90C. The average humidity in the waiting room of the public health center of Bambu is 70.3% while the public health center of Binanga 65%.. The average lighting in the waiting eoom of public health center of Binanga is 215.9 lux and the public health center of Bambu is 139.5 lux. The total number of germs in the waiting room of the public health center of Bambu is on average 258 CFU / m3 while the public health center of Binanga is 513 CFU / m3. Conclusion: the number of bacteria in the waiting room of public health center of Binanga is more than Bambu. Suggestion: health workers and the community to use personal protective equipment (masks) if they are around the public health center

 

Downloads

Download data is not yet available.

References

Abdullah, M. and Hakim, B. (2011) ‘Lingkungan Fisik dan Angka Kuman Udara Ruangan di Rumah Sakit Umum Haji Makassar , Sulawesi Selatan Physical Environment and Microbe Rate of Indoor Air of Makassar Hajj Public Hospital , South Sulawesi’, Jurnal Kesehatan Masyarakat Nasional, 5(5), pp. 206–211.

C.Pommerville, J. (2007) Alcamo’s Laboratory Fundamentals of Microbiology. Eight Edit. sudbury, Massachusetts: Jones And Bartlett Publisher.

Cahyono, T. (2017) Penyehatan Udara. Edited by E. Risanto. Yogyakarta: Penerbit ANDI.

Efendi, V. O. and Efendi, Y. (2013) ‘Mikrobiologi Hasil Perikanan JILID 1’, Bung Hatta University Press, 1(9), pp. 1–106.

Fahimah, R., Kusumowardani, E., & Susanna, D. (2014) ‘Kualitas Udara Rumah dengan Kejadian Pneumonia Anak Bawah Lima Tahun Kualitas Udara Rumah dengan Kejadian Pneumonia Anak Bawah Lima Tahun ( di Puskesmas Cimahi Selatan dan Leuwi Gajah Kota Cimahi ).’, Makara J. Health Res, 18(1), pp. 25–33.

Femy, Budiarti, T. and Nasrullah, N. (2014) ‘Pengaruh Tata Hijau Terhadap Suhu Dan Kelembaban Relatif Udara, Pada Balai Besar Pengembangan Mekanisasi Pertanian, Serpong’, Jurnal Lanskap Indonesia, 6(2), pp. 21–28. doi: 10.29244/jli.2014.6.2.21-28.

Fitria, L. et al. (2008) ‘Kualitas Udara Dalam Ruang Perpustakaan Universitas X Ditinjau Dari Kualitas Biologi, Fisik, Dan Kimiawi’, Lingkungan, Departemen Kesehatan Masyarakat, Fakultas Kesehatan Indonesia, Universitas, 12(2), pp. 76–82.

Ismadiar Rachmatantri, Mochtar Hadiwidodo, H. S. H. (2019) ‘Pengaruh Penggunaan Ventilasi (Ac Dan Non-Ac) Terhadap Keberadaan Mikroorganisme Udara Di Ruang Perpustakaan’, Journal of Chemical Information and Modeling, 53(9), pp. 1689–1699.

Jawetz, Melnick and Adelberg’s (2005) Mikrobiologi Kedokteran. Jakarta: Salemba Medika.

Mayasari, A., Zulkarnain and Agrina (2020) ‘Analisis Lingkungan Fisik Udara Terhadap Angka Kuman Udara Di Rumah Sakit’, Jurnal Ilmu Lingkungan, 13(1), pp. 81–89.

Naddafi, K. et al. (2011) ‘Investigation Of Indoor And Outdoor Air Bactrial Density In Tehran Subway System’, Iranian Journal of Environmental Health Science & Engineering, 8(4), pp. 383–388.

Ningrum, E. K. (2015) ‘Hubungan Kondisi Fisik Rumah Dan Kepadatan Hunian Dengan Kejadian Ispa Non Pneumonia Pada Balita Di Wilayah Kerja Puskesmas Sungai Pinang’, Jurnal Publikasi Kesehatan Masyarakat Indonesia, 2(2), pp. 72–76.

Nugroho, D. A., Budiyono, B. and Nurjazuli, N. (2016) ‘Faktor-faktor yang berhubungan dengan angka kuman udara di ruang rawat inap kelas III RSUD dr. Moewardi surakarta’, Jurnal Kesehatan Masyarakat (Undip); Vol 4, No 4 (2016): JULI. Available at: https://ejournal3.undip.ac.id/index.php/jkm/article/view/14385.

Nurlaela, N. F. N. (2013) ‘Pola Kuman pada Ruang Publik, Ruang Pelayanan, dan Ruang Perawatan Rumah Sakit Penyakit Infeksi Prof. Dr. Sulianti Saroso’, Indonesian Journal of Infectious Disease, 1(3), pp. 14–23. doi: 10.32667/ijid.v1i3.14.

Rahayu, E. P. et al. (2019) ‘Kualitas Udara Dalam Ruang Rawat Inap Di Rumah Sakit Swasta Tipe C Kota Pekanbaru Ditinjau Dari Kualitas Fisik’, Dinamika Lingkungan Indonesia, 6(1), p. 55. doi: 10.31258/dli.6.1.p.55-59.

Shrieve, D. C. and Loeffler, J. S. (2011) Human Radiation Injury. Philadelphia: Lippincott Williams & wilkins, a Wolters Kluwer Business.

Vidyautami, D. ., Huboyo, H. . and Hadiwidodo, M. (2015) ‘Pengaruh Penggunaan Ventilasi (Ac Dan Non Ac) Dalam Ruangan Terhadap Keberadaan Mikroorganisme Udara (Studi Kasus : Ruang Kuliah Jurusan Teknik Sipil Universitas Diponegoro)’, Jurnal Teknik Lingkungan, 4(1), pp. 1–8. Available at: https://www.neliti.com/publications/143280/.

Wulandari, W., Sutomo, A. H. and Iravati, S. (2016) ‘Angka Kuman Udara Dan Lantai Ruang Rawat Inap Rumah Sakit Pku Muhammadiyah Yogyakarta’, Jurnal Berkala Kesehatan, 1(1), pp. 13–20. doi: 10.20527/jbk.v1i1.655.

Yusup, Y., Ahmad, M. I. and Ismail, N. (2014) ‘Indoor Air Quality of Typical Malaysian Open-air Restaurants’, Environment and Pollution, 3(4), pp. 10–23. doi: 10.5539/ep.v3n4p10.

Submitted

2022-01-25

Accepted

2022-04-07

Published

2022-08-31

How to Cite

1.
islam fahrul, ahmad haeranah, askur. Number of Bacteria in the Air of Waiting Room in the Public Health Center. J Keskom [Internet]. 2022 Aug. 31 [cited 2024 Dec. 21];8(2):314-21. Available from: https://jurnal.htp.ac.id/index.php/keskom/article/view/1109